FS#4475 — HG: rbx-97 addition
Scheduled Maintenance Report for Network & Infrastructure
Completed
We will link the network of HG in parallel on
the new router rbx-97-N7.



Update(s):

Date: 2010-08-17 14:15:52 UTC
The prject is suspended until the resolution of problems.

Date: 2010-08-17 10:36:43 UTC
Another incompatibility touch \"ip route\".

Another TAC has been opened for this issue.

It's not tomorrow that we will migrate Cisco 6509
to Nexus 7016 ...



Date: 2010-08-17 10:34:27 UTC
Incompatibilities (bugs? But not) have been put in evidence
on the operation of HSRP + IP proxy-ARP between the
6509/SXI4 and Nexus7016/5.0 (2)

interface VlanXXX
mac-address 00ff.ffff.ff02
ip proxy-arp
ip local-proxy-arp
standby 1 mac-address 00ff.ffff.ff00

interface VlanXXX
mac-address 00ff.ffff.ff01
ip proxy-arp
ip local-proxy-arp
hsrp 1
mac-address 00ff.ffff.ff00

IP Proxy-ARP annonce sur
- 6509 la MAC 00ff.ffff.ff00
- 7016 la MAC 00ff.ffff.ff01

Suddenly there is an incompatibility between two materials in order
to make it functional on the same network. Either one or the other.
Migration can not be done smoothly.

The ideal would be to put in the ip proxy-arp the mac to be announced.

A TAC has been opened for this issue.
Posted Aug 17, 2010 - 09:36 UTC