We have a TCAM exception on the mil-5-6k linecard 2 => we are reloading the card.
mil-5-6k#remote command mod 2 sh platform hard cef exception status
Current IPv4 FIB exception state = TRUE
Current IPv6 FIB exception state = FALSE
Current MPLS FIB exception state = FALSE
Current EoM/VPLS FIB TCAM exception state = FALSE
Update(s):
Date: 2016-12-06 05:40:02 UTC mil-5-6k#remote command mod 1 sh platform hard cef exception status
Current IPv4 FIB exception state = TRUE
Current IPv6 FIB exception state = FALSE
Current MPLS FIB exception state = FALSE
Current EoM/VPLS FIB TCAM exception state = FALSE
mil-5-6k(config)#no power enable module 1
mil-5-6k(config)# power enable module 1
Dans 2-3 semaines nous allons remplacer ce routeur ..
Date: 2016-12-04 10:44:17 UTC
Mod Online Diag Status
---- -------------------
1 Pass
2 Pass
3 Pass
4 Pass
5 Pass
9 Pass
9/0 Pass
9/1 Pass
mil-5-6k#remote command mod 2 sh platform hard cef exception status
Current IPv4 FIB exception state = FALSE
Current IPv6 FIB exception state = FALSE
Current MPLS FIB exception state = FALSE
Current EoM/VPLS FIB TCAM exception state = FALSE
Reload done, the linecard is back to normal operation state.
Date: 2016-12-04 10:39:52 UTC mil-5-6k(config)#no power enable module 2
%Power admin state updated
mil-5-6k(config)#
mil-5-6k(config)#end
mil-5-6k#