FS#4516 — ams-1-6k
Incident Report for Network & Infrastructure
Resolved
We had a problem on the card #2 of ams-1-6k. We are restarting the card in order to diagnose the problem.

Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1671: Aug 26 16:55:10 GMT: %EARL-DFC2-2-SWITCH_BUS_IDLE: Switching bus is idle for 5 seconds. The card grant is 0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1672: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x2C] JA_DR_RI_0_CPU_FIFO_264_16_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1673: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x6B] JA_DR_RI_1_CPU_FIFO_264_16_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1674: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x46] JA_DR_RI_0_STA_FCO = 0x3
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1675: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x85] JA_DR_RI_1_STA_FCO = 0x3
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1676: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0xC8] JA_DR_RW_STA_PB_FC = 0xF
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1677: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0xC9] JA_DR_RW_STA_LO_FULLNESS_0 = 0xB0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1678: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0xCA] JA_DR_RW_STA_HI_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1679: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0xCB] JA_DR_RW_STA_LO_FULLNESS_1 = 0xB8
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1680: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0xCC] JA_DR_RW_STA_HI_FULLNESS_1 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1681: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x150] JA_DT_FD_TXPB_FULLNESS_HI = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1682: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x151] JA_DT_FD_TXPB_FULLNESS_LO = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1683: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x28A] JA_FI_FT_RCV_RATE_SEL = 0xC
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1684: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x261] JA_FI_FR_HI_FULLNESS_A = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1685: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x262] JA_FI_FR_LO_FULLNESS_A = 0x3BA
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1686: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x263] JA_FI_FR_HI_FULLNESS_B = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1687: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x264] JA_FI_FR_LO_FULLNESS_B = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1688: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x289] JA_FI_FT_XMIT_SHAPE = 0xFFF
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1689: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x283] JA_FI_FT_HI_FULL_A = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1690: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x284] JA_FI_FT_LO_FULL_A = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1691: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x285] JA_FI_FT_HI_FULL_B = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1692: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x286] JA_FI_FT_LO_FULL_B = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1693: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x348] JA_TI_PR_RPT_HI_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1694: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x349] JA_TI_PR_RPT_LO_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1695: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x462] JA_AG_DI_MACN_0_FIFO_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1696: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x463] JA_AG_DI_MACN_1_FIFO_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1697: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x489] JA_AG_DS_RAM_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1698: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x48A] JA_AG_DS_RAM_FULLNESS_1 = 0xA
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1699: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x48B] JA_AG_DS_RAM_FULLNESS_2 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1700: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x48C] JA_AG_DS_RAM_FULLNESS_3 = 0x14
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1701: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x4CB] JA_AG_PM_RAM_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1702: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x4CC] JA_AG_PM_RAM_FULLNESS_1 = 0x101
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1703: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x4CD] JA_AG_PM_RAM_FULLNESS_2 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1704: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x4CE] JA_AG_PM_RAM_FULLNESS_3 = 0x101
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1705: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x4F1] JA_AG_RM_RAM_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1706: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x4F2] JA_AG_RM_RAM_FULLNESS_1 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1707: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x4F3] JA_AG_RM_RAM_FULLNESS_2 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1708: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x4F4] JA_AG_RM_RAM_FULLNESS_3 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1709: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x502] JA_AG_RS_RAM_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1710: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x503] JA_AG_RS_RAM_FULLNESS_1 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1711: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x504] JA_AG_RS_RAM_FULLNESS_2 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1712: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x505] JA_AG_RS_RAM_FULLNESS_3 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1713: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x50C] JA_EI_DQ_SF_FIFO_CMT_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1714: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x50D] JA_EI_DQ_SF_FIFO_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1715: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x55D] JA_EI_RG_STA_FM_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1716: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x55E] JA_EI_RG_STA_FM_FULLNESS_1 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1717: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x573] JA_EI_SR_125_STA_E_RSLT_FIFO_FULLNESS = 0x22
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1718: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x594] JA_EI_SR_78_STA_MAPPING_FIFO_FULLNESS = 0x1E
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1719: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x599] JA_EI_TX_STA_LR_DYN_FIFO_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1720: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x59A] JA_EI_TX_STA_LR_DYN_FIFO_FULLNESS_1 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1721: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x59B] JA_EI_TX_STA_LR_DYN_FIFO_FULLNESS_2 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1722: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x59C] JA_EI_TX_STA_LR_DYN_FIFO_FULLNESS_3 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1723: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x5A6] JA_EI_TX_STA_MO_DYN_FIFO_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1724: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x5A7] JA_EI_TX_STA_MO_DYN_FIFO_FULLNESS_1 = 0xA
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1725: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x5A8] JA_EI_TX_STA_MO_DYN_FIFO_FULLNESS_2 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1726: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x5A9] JA_EI_TX_STA_MO_DYN_FIFO_FULLNESS_3 = 0x14
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1727: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x5B3] JA_EI_TX_STA_CT_DYN_FIFO_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1728: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x5B4] JA_EI_TX_STA_CT_DYN_FIFO_FULLNESS_1 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1729: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x5B5] JA_EI_TX_STA_CT_DYN_FIFO_FULLNESS_2 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1730: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x5B6] JA_EI_TX_STA_CT_DYN_FIFO_FULLNESS_3 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1731: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x5F6] JA_TM_HI_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1732: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [0:0x5F7] JA_TM_LO_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1733: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x2C] JA_DR_RI_0_CPU_FIFO_264_16_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1734: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x6B] JA_DR_RI_1_CPU_FIFO_264_16_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1735: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x46] JA_DR_RI_0_STA_FCO = 0x3
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1736: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x85] JA_DR_RI_1_STA_FCO = 0x3
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1737: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0xC8] JA_DR_RW_STA_PB_FC = 0xF
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1738: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0xC9] JA_DR_RW_STA_LO_FULLNESS_0 = 0xB9
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1739: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0xCA] JA_DR_RW_STA_HI_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1740: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0xCB] JA_DR_RW_STA_LO_FULLNESS_1 = 0xB4
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1741: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0xCC] JA_DR_RW_STA_HI_FULLNESS_1 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1742: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x150] JA_DT_FD_TXPB_FULLNESS_HI = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1743: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x151] JA_DT_FD_TXPB_FULLNESS_LO = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1744: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x28A] JA_FI_FT_RCV_RATE_SEL = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1745: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x261] JA_FI_FR_HI_FULLNESS_A = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1746: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x262] JA_FI_FR_LO_FULLNESS_A = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1747: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x263] JA_FI_FR_HI_FULLNESS_B = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1748: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x264] JA_FI_FR_LO_FULLNESS_B = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1749: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x289] JA_FI_FT_XMIT_SHAPE = 0xFC7
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1750: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x283] JA_FI_FT_HI_FULL_A = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1751: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x284] JA_FI_FT_LO_FULL_A = 0x380
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1752: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x285] JA_FI_FT_HI_FULL_B = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1753: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x286] JA_FI_FT_LO_FULL_B = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1754: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x348] JA_TI_PR_RPT_HI_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1755: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x349] JA_TI_PR_RPT_LO_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1756: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x462] JA_AG_DI_MACN_0_FIFO_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1757: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x463] JA_AG_DI_MACN_1_FIFO_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1758: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x489] JA_AG_DS_RAM_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1759: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x48A] JA_AG_DS_RAM_FULLNESS_1 = 0x1
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1760: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x48B] JA_AG_DS_RAM_FULLNESS_2 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1761: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x48C] JA_AG_DS_RAM_FULLNESS_3 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1762: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x4CB] JA_AG_PM_RAM_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1763: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x4CC] JA_AG_PM_RAM_FULLNESS_1 = 0x2F
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1764: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x4CD] JA_AG_PM_RAM_FULLNESS_2 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1765: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x4CE] JA_AG_PM_RAM_FULLNESS_3 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1766: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x4F1] JA_AG_RM_RAM_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1767: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x4F2] JA_AG_RM_RAM_FULLNESS_1 = 0x1
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1768: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x4F3] JA_AG_RM_RAM_FULLNESS_2 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1769: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x4F4] JA_AG_RM_RAM_FULLNESS_3 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1770: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x502] JA_AG_RS_RAM_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1771: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x503] JA_AG_RS_RAM_FULLNESS_1 = 0x1
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1772: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x504] JA_AG_RS_RAM_FULLNESS_2 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1773: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x505] JA_AG_RS_RAM_FULLNESS_3 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1774: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x50C] JA_EI_DQ_SF_FIFO_CMT_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1775: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x50D] JA_EI_DQ_SF_FIFO_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1776: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x55D] JA_EI_RG_STA_FM_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1777: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x55E] JA_EI_RG_STA_FM_FULLNESS_1 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1778: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x573] JA_EI_SR_125_STA_E_RSLT_FIFO_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1779: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x594] JA_EI_SR_78_STA_MAPPING_FIFO_FULLNESS = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1780: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x599] JA_EI_TX_STA_LR_DYN_FIFO_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1781: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x59A] JA_EI_TX_STA_LR_DYN_FIFO_FULLNESS_1 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1782: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x59B] JA_EI_TX_STA_LR_DYN_FIFO_FULLNESS_2 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1783: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x59C] JA_EI_TX_STA_LR_DYN_FIFO_FULLNESS_3 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1784: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x5A6] JA_EI_TX_STA_MO_DYN_FIFO_FULLNESS_0 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1785: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x5A7] JA_EI_TX_STA_MO_DYN_FIFO_FULLNESS_1 = 0x0
Aug 26 17:55:28 40g.ams-1-6k.routers.ovh.net 1786: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x5A8] JA_EI_TX_STA_MO_DYN_FIFO_FULLNESS_2 = 0x0
Aug 26 17:55:29 40g.ams-1-6k.routers.ovh.net 1787: Aug 26 16:55:10 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x5A9] JA_EI_TX_STA_MO_DYN_FIFO_FULLNESS_3 = 0x0
Aug 26 17:55:29 40g.ams-1-6k.routers.ovh.net 1788: Aug 26 16:55:11 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x5B3] JA_EI_TX_STA_CT_DYN_FIFO_FULLNESS_0 = 0x0
Aug 26 17:55:29 40g.ams-1-6k.routers.ovh.net 1789: Aug 26 16:55:11 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x5B4] JA_EI_TX_STA_CT_DYN_FIFO_FULLNESS_1 = 0x0
Aug 26 17:55:29 40g.ams-1-6k.routers.ovh.net 1790: Aug 26 16:55:11 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x5B5] JA_EI_TX_STA_CT_DYN_FIFO_FULLNESS_2 = 0x0
Aug 26 17:55:29 40g.ams-1-6k.routers.ovh.net 1791: Aug 26 16:55:11 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x5B6] JA_EI_TX_STA_CT_DYN_FIFO_FULLNESS_3 = 0x0
Aug 26 17:55:29 40g.ams-1-6k.routers.ovh.net 1792: Aug 26 16:55:11 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x5F6] JA_TM_HI_FULLNESS = 0x0
Aug 26 17:55:29 40g.ams-1-6k.routers.ovh.net 1793: Aug 26 16:55:11 GMT: %PF_ASIC-DFC2-3-ASIC_DUMP: [1:0x5F7] JA_TM_LO_FULLNESS = 0x0


Update(s):

Date: 2010-08-29 10:42:42 UTC
The card is replaced and ports are up except the port 3 (to AMSIX) ...
because of XENPAK stuck in the old card! We will have to use other tools to extract it.
Meanwhile, we focus a little the card by interrupting temporarily the traffic on certain ports of other cards.
We have indeed noticed that the problem manifested itself from a certain threshold of traffic passing through the card.



Date: 2010-08-29 10:31:14 UTC
The technician has just arrived on site. We replace the card in the slot2.



Date: 2010-08-27 09:19:23 UTC
Despite the absence of any defect on the card , we had the same reports
on that card this evening and then nothing. The problem seemed to be
linked to the trafic poured on this cards. So we had cut some links
on other cards in order to report the trafic on the \"doubtful\" card
and we had reproducted the problem.

We had effectively a hardware problem on this card.
We are organizing a replacement by a technician on the spot.

Date: 2010-08-27 09:03:05 UTC
After the reset we have no detected default on the card. We keep the router under surveillance. We will trigger an intervention for the replacement of the card if necessary.
Posted Aug 27, 2010 - 09:00 UTC