FS#8445 — vss-3-6k
Scheduled Maintenance Report for Network & Infrastructure
Completed
2 cards broke down following the router update.

Update(s):

Date: 2013-04-17 14:40:45 UTC
The card has booted:

Mod Online Diag Status
---- -------------------
3 Pass

Date: 2013-04-17 11:29:38 UTC
Apr 17 11:41:12 GMT: %ONLINE-SP-6-REGN_TIMER: Module 3, Proc. 0.
Failed to bring online because of registration timer event
sm(cygnus_oir_bay slot3), running yes, state wait_til_online
Last transition recorded: (remove)-> empty (remove)->
empty_clr_persist (remove)-> empty (insert)-> may_be_occupied
(timer)-> occupied (known)-> can_power_on (yes_power)-> powered_on
(real_power_on)-> check_power_on (timer)-> check_power_on
(power_on_ok)-> wait_til_online
Apr 17 11:41:12 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 3
set off (Module Failed SCP dnld)

We change the DFC.

Date: 2013-04-17 09:48:20 UTC
We are changing the memory card of the card 3 of vss-3-6k.

Date: 2013-04-17 09:28:14 UTC
Cards are replaced. We reboot the router.

Date: 2013-04-16 17:35:16 UTC
All cards are up:

vss-3-6k#sh mod
Mod Ports Card Type Model
Serial No.
--- ----- -------------------------------------- ------------------
-----------
1 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE
SAL1407B2T6
2 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE
SAL12372NTN
3 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX
SAL1137ZYHK
5 5 Supervisor Engine 720 10GE (Active) VS-S720-10G
SAL1406AYJR
6 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE
SAL1407B1B2
7 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX
SAL08486L6X

Mod MAC addresses Hw Fw Sw
Status
--- ---------------------------------- ------ ------------
------------ -------
1 8843.e1aa.b9c8 to 8843.e1aa.b9cb 3.1 12.2(14r)S5
12.2(33)SXI1 Ok
2 0022.90dd.d7e8 to 0022.90dd.d7eb 2.7 12.2(14r)S5
12.2(33)SXI1 Ok
3 001d.4549.6ae0 to 001d.4549.6b0f 2.6 12.2(18r)S1
12.2(33)SXI1 Ok
5 0024.14e4.c390 to 0024.14e4.c397 3.1 8.5(3)
12.2(33)SXI1 Ok
6 8843.e1b0.ecb4 to 8843.e1b0.ecb7 3.1 Unknown Unknown
PwrDown
7 0012.7f29.8818 to 0012.7f29.8847 2.1 12.2(14r)S5
12.2(33)SXI1 Ok

Mod Sub-Module Model Serial Hw
Status
---- --------------------------- ------------------ -----------
------- -------
1 Distributed Forwarding Card WS-F6700-DFC3CXL SAL1406AVCQ 1.6
Ok
2 Distributed Forwarding Card WS-F6700-DFC3CXL SAL1251DDJY 1.2
Ok
3 Distributed Forwarding Card WS-F6700-DFC3CXL SAL1251DDL8 1.2
Ok
5 Policy Feature Card 3 VS-F6K-PFC3CXL SAL1406ANRB 1.2
Ok
5 MSFC3 Daughterboard VS-F6K-MSFC3 SAL1406AYTZ 2.1
Ok
6 Distributed Forwarding Card WS-F6700-DFC3CXL SAL1406AVDG 1.6
PwrDown
7 Distributed Forwarding Card WS-F6700-DFC3CXL SAL12437JLR 1.1
Ok

Mod Online Diag Status
---- -------------------
1 Pass
2 Pass
3 Pass
5 Pass
6 Not Applicable
7 Pass

Date: 2013-04-16 17:34:19 UTC
Done.

We now change module 7.

Date: 2013-04-16 17:17:26 UTC
We change module 3.

Date: 2013-04-15 13:19:06 UTC
Apr 15 10:40:44 GMT: %ONLINE-SP-6-REGN_TIMER: Module 3, Proc. 0.
Failed to bring online because of registration timer event
sm(cygnus_oir_bay slot3), running yes, state wait_til_online
Last transition recorded: (disabled)-> disabled (disabled)-> disabled2
(restart)-> wait_til_disabled (timer)-> may_be_occupied (timer)->
occupied (known)-> can_power_on (yes_power)-> powered_on
(real_power_on)-> check_power_on (timer)-> check_power_on
(power_on_ok)-> wait_til_online
Apr 15 10:40:44 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 3
set off (Module Failed SCP dnld)
Apr 15 10:40:46 GMT: %ONLINE-SP-6-REGN_TIMER: Module 7, Proc. 0.
Failed to bring online because of registration timer event
sm(cygnus_oir_bay slot7), running yes, state wait_til_online
Last transition recorded: (disabled)-> disabled (disabled)-> disabled2
(restart)-> wait_til_disabled (timer)-> may_be_occupied (timer)->
occupied (known)-> can_power_on (yes_power)-> powered_on
(real_power_on)-> check_power_on (timer)-> check_power_on
(power_on_ok)-> wait_til_online
Apr 15 10:40:46 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 7
set off (Module Failed SCP dnld)
Posted Apr 15, 2013 - 13:18 UTC