gsw-1

Incident Report for Network & Infrastructure

Resolved

La carte 3 du routeur ne fonctionne pas correctement. Le routeur
a ordonné le reboot.

Sep 18 23:25:10 GMT: %CPU_MONITOR-SP-6-NOT_HEARD: CPU_MONITOR messages have not been heard for 31 seconds [3/0]
Sep 18 23:25:40 GMT: %CPU_MONITOR-SP-6-NOT_HEARD: CPU_MONITOR messages have not been heard for 61 seconds [3/0]
Sep 18 23:26:10 GMT: %CPU_MONITOR-SP-6-NOT_HEARD: CPU_MONITOR messages have not been heard for 91 seconds [3/0]
Sep 18 23:26:27 GMT: %FIB-3-FIBDISABLE: Fatal error, slot/cpu 3/0: IPC Failure: timeout
Sep 18 23:26:40 GMT: %CPU_MONITOR-SP-6-NOT_HEARD: CPU_MONITOR messages have not been heard for 121 seconds [3/0]
Sep 18 23:27:10 GMT: %CPU_MONITOR-SP-6-NOT_HEARD: CPU_MONITOR messages have not been heard for 151 seconds [3/0]
Sep 18 23:27:40 GMT: %CPU_MONITOR-SP-3-TIMED_OUT: CPU_MONITOR messages have failed, resetting module [3/0]
Sep 18 23:27:40 GMT: %OIR-SP-3-PWRCYCLE: Card in module 3, is being power-cycled off (Heartbeat Messages Not Received From Module)
Sep 18 23:27:40 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Heartbeat Messages Not Received From Module)


Update(s):

Date: 2009-09-19 10:24:24 UTC
Le 2ème 10G vers Orange est basculé sur la carte #7 qui disposait d'un port libre. Le trafic vers Orange revient à la normale.

Date: 2009-09-19 09:45:04 UTC
La carte est morte.

On bouge les ports sur les ports disponibles sur le routeur.
On recoit les nouvelles cartes spares Mardi. Ca tombe toujours
au bon moment ...

Date: 2009-09-19 09:03:51 UTC
Sep 19 02:14:18 GMT: %CPU_MONITOR-SP-6-NOT_HEARD: CPU_MONITOR messages have not been heard for 30 seconds [3/0]
Sep 19 02:14:38 GMT: %OIR-SP-3-PWRCYCLE: Card in module 3, is being power-cycled off (Reset - Module Reloaded During Download)
Sep 19 02:14:38 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Reset - Module Reloaded During Download)
Sep 19 02:18:50 GMT: %ONLINE-SP-6-TIMER: Module 3, Proc. 0. Failed to bring online because of timer event
Sep 19 02:18:50 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Module Failed SCP dnld)
Sep 19 02:23:01 GMT: %ONLINE-SP-6-TIMER: Module 3, Proc. 0. Failed to bring online because of timer event
Sep 19 02:23:01 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Module Failed SCP dnld)
Sep 19 02:27:12 GMT: %ONLINE-SP-6-TIMER: Module 3, Proc. 0. Failed to bring online because of timer event
Sep 19 02:27:12 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Module Failed SCP dnld)
Sep 19 02:31:23 GMT: %ONLINE-SP-6-TIMER: Module 3, Proc. 0. Failed to bring online because of timer event
Sep 19 02:31:23 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Module Failed SCP dnld)


Date: 2009-09-18 22:31:10 UTC
up. on surveille.

Sep 18 23:29:22 GMT: %DIAG-SP-6-RUN_MINIMUM: Module 3: Running Minimal Diagnostics...
Posted Sep 18, 2009 - 22:29 UTC