OVHcloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance

FS#5160 — rbx-g1/g2

Scheduled Maintenance Report for Network & Infrastructure

Completed

We have a problem on the 2 ASR of Roubaix :

Feb 17 17:41:30 rbx-g2-a9.fr.eu 112524: RP/0/RSP0/CPU0:Feb 17 16:41:06
UTC: ospf[1009]: %ROUTING-OSPF-3-INTERNALERR : Internal error, path id
out of range
Feb 17 17:41:30 rbx-g1-a9.fr.eu 158790: RP/0/RSP0/CPU0:Feb 17 16:41:06
UTC: ospf[1009]: %ROUTING-OSPF-3-INTERNALERR : Internal error, path id
out of range
Feb 17 17:41:30 rbx-g2-a9.fr.eu 112525: RP/0/RSP0/CPU0:Feb 17 16:41:06
UTC: ospf[1009]: %ROUTING-OSPF-3-INTERNALERR : Internal error, path id
out of range
Feb 17 17:41:30 rbx-g1-a9.fr.eu 158791: RP/0/RSP0/CPU0:Feb 17 16:41:06
UTC: ospf[1009]: %ROUTING-OSPF-3-INTERNALERR : Internal error, path id
out of range
Feb 17 17:41:30 rbx-g2-a9.fr.eu 112526: RP/0/RSP0/CPU0:Feb 17 16:41:06
UTC: ospf[1009]: %ROUTING-OSPF-3-INTERNALERR : Internal error, path id
out of range
Feb 17 17:41:30 rbx-g1-a9.fr.eu 158792: RP/0/RSP0/CPU0:Feb 17 16:41:06
UTC: ospf[1009]: %ROUTING-OSPF-3-INTERNALERR : Internal error, path id
out of range
Feb 17 17:41:30 rbx-g2-a9.fr.eu 112527: RP/0/RSP0/CPU0:Feb 17 16:41:06
UTC: ospf[1009]: %ROUTING-OSPF-3-INTERNALERR : Internal error, path id
out of range
Feb 17 17:41:30 rbx-g1-a9.fr.eu 158793: RP/0/RSP0/CPU0:Feb 17 16:41:06
UTC: ospf[1009]: %ROUTING-OSPF-3-INTERNALERR : Internal error, path id
out of range
Feb 17 17:41:30 rbx-g2-a9.fr.eu 112528: RP/0/RSP0/CPU0:Feb 17 16:41:06
UTC: ospf[1009]: %ROUTING-OSPF-3-INTERNALERR : Internal error, path id
out of range
Feb 17 17:41:30 rbx-g1-a9.fr.eu 158794: RP/0/RSP0/CPU0:Feb 17 16:41:06
UTC: ospf[1009]: %ROUTING-OSPF-3-INTERNALERR : Internal error, path id
out of range

We are going to restart them.


Update(s):

Date: 2011-02-17 23:55:25 UTC
Right, that version isn't released yet. It is due out shortly. I think its due out end of April.

heheh :)

Date: 2011-02-17 18:50:29 UTC
4.0.2 not available yet ...

Date: 2011-02-17 18:49:57 UTC
CSCtn00523

This is integrated in 4.0.2.

Symptom:
- OSPF process stuck in an endless cycle, not computing any more
routes and do not reacting to the network changes

burst of syslog messages;
Jan 31 03:05:33.798 : ospf[1009]: %ROUTING-OSPF-3-INTERNALERR :
Internal error, path id out of range

Conditions:
- Type-3/5/7 LSA changing it's mask multiple times

Workaround:
- prevent prefixes in Type-3/5/7 LSAs to change their mask

Recovery:
- process restart OSPF process

Date: 2011-02-17 18:48:59 UTC
A cisco engineer is seraching the cause of the problem.
As we are in the last version of the soft, it smelles like
a bug so far.

Date: 2011-02-17 18:42:07 UTC
Done

Date: 2011-02-17 18:41:45 UTC
Back. It's better.

G2 in reboot.

Date: 2011-02-17 18:39:46 UTC
rbx-g1 is restarting.
Posted Feb 17, 2011 - 18:39 UTC