Get webhook notifications whenever Network & Infrastructure creates an incident, updates an incident, resolves an incident or changes a component status.
Reason: Reset triggered due to HA policy of Reset
System version: 7.0(5)N1(1a)
Service: ptplc hap reset
Nous planifions updater ce switch en priorité.
Update(s):
Date: 2016-10-25 00:43:36 UTC Quelque port était en erreur vpc, tout est fixé. Le service est rétablit.
Date: 2016-10-24 23:48:12 UTC bhs2-21b-n56 vien de rebooter
Date: 2016-10-24 23:41:26 UTC Le service est revenu à la normale
Date: 2016-10-24 23:25:56 UTC 117768 Eth116/1/9 up failed Compatibility check failed -
117776 Eth116/1/17 up failed Compatibility check failed -
117778 Eth116/1/19 up failed Compatibility check failed -
117788 Eth116/1/29 up failed Compatibility check failed -
117791 Eth116/1/32 up failed Compatibility check failed -
117793 Eth116/1/34 up failed Compatibility check failed -
117798 Eth116/1/39 up failed Compatibility check failed -
Plusieurs ports ont des inconsistence entre les 2 switches (redondance vpc)
bhs2-21a-n56# sh vpc consistency-parameters interface Eth116/1/19
Legend:
Type 1 : vPC will be suspended in case of mismatch
Name Type Local Value Peer Value
------------- ---- ---------------------- -----------------------
Speed 1 1000 Mb/s 10 Mb/s
Duplex 1 full full
Port Mode 1 trunk trunk
Native Vlan 1 6 6
MTU 1 1500 1500
Admin port mode 1 pvlan trunk sec pvlan trunk sec
Shut Lan 1 No No
vPC card type 1 Empty Empty
Allowed VLANs - 117,316 117,316
Local suspended VLANs - 117,316 -
Nous tentons un shut/no shut massif sur les ports \"failed\"
Date: 2016-10-24 23:24:31 UTC Certain serveurs semble down du côté bhs2-21a. tout est ok sur le côté b.