Nous avons constaté une TCAM exception sur la DFC 3 de mad-5-6k:
mad-5-6k-dfc3#sh platform hardware cef exception status
Current IPv4 FIB exception state = TRUE
Current IPv6 FIB exception state = FALSE
Current MPLS FIB exception state = FALSE
Current EoM/VPLS FIB TCAM exception state = FALSE
Ceci entraine des pertes de paquets en fonction des destinations.
Nous venons de redémarrer la carte en question et le problème n'est plus présent:
mad-5-6k-dfc3#sh platform hardware cef exception status
Current IPv4 FIB exception state = FALSE
Current IPv6 FIB exception state = FALSE
Current MPLS FIB exception state = FALSE
Current EoM/VPLS FIB TCAM exception state = FALSE