OVHCloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
FS#17753 — ldn-1-n7
Scheduled Maintenance Report for Network & Infrastructure
Completed
Following task https://status.ovh.net/?do=details&id=12718

We have detected a bug cotaining LACP in the current version:
\"
Symptom:
LACP PDUs not received by the CPU. As a results, port-channel members are suspended.

Nexus# show system internal pktmgr internal event-history lcache-err
No Memory available for pcm entry ifindex
\"
We will update ldn-1-n7 in ISSU to prod the second 100G link towards LINX EXTREME.

During the update, traffic will be taken care of by ldn-5-n7.

Update(s):

Date: 2016-04-28 17:31:19 UTC
The installation has been performed correctly.

We are launching traffic.

Date: 2016-04-28 17:28:12 UTC
Install has been successful.
ldn-1-n7#

We are launching traffic.

Date: 2016-04-28 17:27:52 UTC
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive rolling
2 yes non-disruptive rolling
3 yes non-disruptive reset
4 yes non-disruptive reset
5 yes non-disruptive rolling
6 yes non-disruptive rolling


Do you want to continue with the installation (y/n)? [n] y

-> Go!

Date: 2016-04-28 17:27:48 UTC
The isolation of ports with the port lacp-fast (not supported in ISSU) was performed on ldn-1-n7.
Posted Apr 28, 2016 - 17:26 UTC