FS#16337 — Chicago, IL, US backbone routers
Scheduled Maintenance Report for Network & Infrastructure
Completed
In order to prepare the next implementation of 100G links between Chicago, IL, US and the rest of our POPs, we will replace our existing equipment by 2 couples ASR 9904 + Nexus7706.
The new entity will have a 1,6T routing capability.

We will start migrating chi-2-6k.

During this migration traffic will flow through chi-1-6k.

Update(s):

Date: 2016-01-27 20:13:05 UTC
We are good for chi-5-a9.
We will continue migration tomorrow at the same time, to migrate chi-1-6k on chi-1-a9/chi-1-n7.

CDN Traffic will be redirected to the other POPs.

Date: 2016-01-27 20:11:15 UTC
We have re-activated BGP with our different peers on Equinix as well as with TATA and COMCAST.

Date: 2016-01-27 20:09:27 UTC
All the links are up and the optical levels are good.
We have re-activated traffic on chi-5-n7.

Date: 2016-01-27 20:08:56 UTC
> fping chi-5-a9 chi-5-n7
chi-5-a9 is alive
chi-5-n7 is alive

Date: 2016-01-27 20:08:41 UTC
The router is isolated. We are starting migration with la Chacha team onsite.

Date: 2016-01-27 20:07:50 UTC
We are isolating chi-2-6k.
Posted Jan 27, 2016 - 20:07 UTC