FS#9195 — vac1-n7
Scheduled Maintenance Report for Network & Infrastructure
Completed
We have received a new version of the software
that runs the Cisco Nexus 7009, which allows us to
do things that interest us very much. So we will
be updating the chassis and all the contexts.

The update is done instantly. BGP sessions may
reload during the update. This is also the aim
of the operation - verifying the HA level during
the infrastructure software update.


Update(s):

Date: 2013-08-23 22:44:41 UTC
done.

packet lost for the customer:
6456 packets transmitted, 6456 received, 0% packet loss, time 6496336ms

packet lost on context 1:
6481 packets transmitted, 6480 received, 0% packet loss, time 6521190ms

packet lost on context 2:
6440 packets transmitted, 6386 received, 0% packet loss, time 6478143ms

Just amazing .. a real ISSU that works as thunder. I like Nexus 7000 :)

Date: 2013-08-23 22:42:49 UTC
Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive reset
2 yes non-disruptive reset
3 yes non-disruptive rolling
4 yes non-disruptive rolling
6 yes non-disruptive rolling
8 yes non-disruptive rolling

Date: 2013-08-23 22:42:34 UTC
VAC1: done
VAC3: done

VAC2: in progress

Date: 2013-08-23 22:42:13 UTC
Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive reset
2 yes non-disruptive reset
3 yes non-disruptive rolling
4 yes non-disruptive rolling
6 yes non-disruptive rolling
8 yes non-disruptive rolling

Date: 2013-08-23 17:14:18 UTC
\"Switching over onto standby\".
[7439184.932200] writing reset reason 7, SAP(93): Swover due to
install


Date: 2013-08-23 17:11:48 UTC
Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive reset
2 yes non-disruptive reset
3 yes non-disruptive rolling
4 yes non-disruptive rolling
6 yes non-disruptive rolling
8 yes non-disruptive rolling

Date: 2013-08-23 17:11:36 UTC
Notifying services about system upgrade. [# ] 0% -- FAIL.
Return code 0x41180057 (
The running configuration has inactive policies, which need to be removed
you can view them using 'show running-config aclmgr inactive-if-config'
you can remove them using 'clear inactive config acl/qos`
).

Service \"aclmgr\" in vdc 4:
The running configuration has inactive policies, which need to be removed
you can view them using 'show running-config aclmgr inactive-if-config'
you can remove them using 'clear inactive config acl/qos`


Pre-upgrade check failed. Return code 0x41180057 (
The running configuration has inactive policies, which need to be removed
you can view them using 'show running-config aclmgr inactive-if-config'
you can remove them using 'clear inactive config acl/qos`
).
Posted Aug 23, 2013 - 17:11 UTC