FS#17729 — EQUINIX IX NY 100G, NJ, US
Scheduled Maintenance Report for Network & Infrastructure
Completed
We will replace the current 4*10G of the New York EQUINIX IX exchange point with 1*100G.
The New York POP is a \"satellite\" of Newark, we decided to directly connect this exchange point on Newark to improve the redundancy of the latter.
In addition, it will allow us not to be limited in bandwidth on this exchange point (now the New York POP is connected via 10G DWDM).
During this maintenance traffic will be rerouted on other exchange points.

Update(s):

Date: 2016-04-26 18:01:19 UTC
In roduction:

nwk-5-n7# sh inter Eth6/1 | i rate
30 seconds input rate 4811029552 bits/sec, 1438534 packets/sec
30 seconds output rate 15706178192 bits/sec, 1916407 packets/sec
input rate 4.81 Gbps, 1.44 Mpps; output rate 15.71 Gbps, 1.92 Mpps
300 seconds input rate 5021013056 bits/sec, 1460279 packets/sec
300 seconds output rate 16184480568 bits/sec, 1953127 packets/sec
input rate 5.02 Gbps, 1.46 Mpps; output rate 16.18 Gbps, 1.95 Mpps
nwk-5-n7# sh inter Eth6/1 | i CRC
0 runts 0 giants 0 CRC/FCS 0 no buffer

bonus: we gained 16G between NWK and NYK!

Date: 2016-04-26 17:59:50 UTC
We are isolating traffic on the point of exchange.
Posted Apr 26, 2016 - 17:59 UTC