Get webhook notifications whenever Network & Infrastructure creates an incident, updates an incident, resolves an incident or changes a component status.
The router's cpu level is high.
This is causing a loss of ping.
We are investigating.
Update(s):
Date: 2013-02-11 23:39:39 UTC The router is now stable.
vss-2-6k#sh processes cpu sorted
CPU utilization for five seconds: 74%/23%; one minute: 68%; five minutes: 72%
PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process
3 14748 43110 342 16.29% 11.95% 3.51% 23 SSH Process
362 866324308 21232715 40801 6.54% 5.81% 5.16% 0 CEF: IPv4 proces
11 1093090180 867509502 1260 3.67% 6.45% 7.61% 0 ARP Input
566 311379740 176960817 1759 3.51% 2.41% 3.62% 0 BGP Router
Date: 2013-02-11 23:39:22 UTC We are removing the ipv6 announcements on the vlans clients to relieve the router.
vss-2-6k#conf t
Enter configuration commands, one per line. End with CNTL/Z.
vss-2-6k(config)#interface Vlan859
vss-2-6k(config-if)# ipv6 nd ra suppress
vss-2-6k(config)#interface Vlan860
vss-2-6k(config-if)# ipv6 nd ra suppress
vss-2-6k(config)#interface Vlan861
vss-2-6k(config-if)# ipv6 nd ra suppress