OVHCloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
FS#13727 — nexus 176.31.236.0/24 et 176.31.237.0/24
Scheduled Maintenance Report for Network & Infrastructure
Completed
We need to update the n5548 couple that manages these 2 networks.
A bug en 6.0(2)N2(2) caused some chassis ports to go down and stay down.

Currently 3 FEX have been single homed by the bug. There's no impact on production but the 3 FEXs are no longer redundant.

To prepare for the ISSU update (hitless), we're going to reboot the Nexus module 2 which has its ports down.
Hopefully this will be enough to get the ports back up. If not, we'll need to fully reload the chassis.

Afterwards, we will update to 7.0.5.N1a.

The intervention will begin in a few minutes.

Update(s):

Date: 2015-06-23 12:10:16 UTC
Wow!
Update now complete - 3 hours ...

# sh fex
FEX FEX FEX FEX Fex
Number Description State Model Serial
------------------------------------------------------------------------
100 FEX0100 Online N2K-C2248TP-1GE SSI1444081Y
101 FEX0101 Online N2K-C2248TP-1GE SSI1444081S
102 FEX0102 Online N2K-C2248TP-1GE SSI15330JJV
103 FEX0103 Online N2K-C2248TP-1GE SSI153508ET
104 FEX0104 Online N2K-C2248TP-1GE SSI15391ATG
105 FEX0105 Online N2K-C2232PP-10GE SSI1541037V
106 FEX0106 Online N2K-C2232PP-10GE SSI14160FXW
107 FEX0107 Online N2K-C2232PP-10GE SSI153409GJ
108 FEX0108 Online N2K-C2232PP-10GE SSI14160MT9
109 FEX0109 Online N2K-C2232PP-10GE SSI154103G2
110 FEX0110 Online N2K-C2232PP-10GE SSI15380LY5
111 FEX0111 Online N2K-C2248TP-1GE SSI144506KC
112 FEX0112 Online N2K-C2232PP-10GE SSI154309WX
113 FEX0113 Online N2K-C2232TM-E-10GE SSI18420A01
114 FEX0114 Online N2K-C2232TM-E-10GE SSI1845091Q
115 FEX0115 Online N2K-C2232TM-E-10GE SSI184906NR
116 FEX0116 Online N2K-C2232TM-E-10GE SSI185007M9
117 FEX0117 Online N2K-C2232TM-E-10GE SSI184906NQ

Date: 2015-06-23 12:09:54 UTC
reload power cycle done. remounting the FEXs

# sh fex
FEX FEX FEX FEX Fex
Number Description State Model Serial
------------------------------------------------------------------------
100 FEX0100 Connected N2K-C2248TP-1GE SSI1444081Y
101 FEX0101 Online N2K-C2248TP-1GE SSI1444081S
102 FEX0102 Connected N2K-C2248TP-1GE SSI15330JJV
103 FEX0103 Connected N2K-C2248TP-1GE SSI153508ET
104 FEX0104 Connected N2K-C2248TP-1GE SSI15391ATG
105 FEX0105 Connected N2K-C2232PP-10GE SSI1541037V
106 FEX0106 Connected N2K-C2232PP-10GE SSI14160FXW
107 FEX0107 Connected N2K-C2232PP-10GE SSI153409GJ
108 FEX0108 Connected N2K-C2232PP-10GE SSI14160MT9
109 FEX0109 Connected N2K-C2232PP-10GE SSI154103G2
110 FEX0110 Connected N2K-C2232PP-10GE SSI15380LY5
111 FEX0111 Connected N2K-C2248TP-1GE SSI144506KC
112 FEX0112 Connected N2K-C2232PP-10GE SSI154309WX
113 FEX0113 Online N2K-C2232TM-E-10GE SSI18420A01
114 FEX0114 Connected N2K-C2232TM-E-10GE SSI1845091Q
115 FEX0115 Connected N2K-C2232TM-E-10GE SSI184906NR
116 FEX0116 Connected N2K-C2232TM-E-10GE SSI185007M9
117 FEX0117 Connected N2K-C2232TM-E-10GE SSI184906NQ

Date: 2015-06-23 12:09:32 UTC
All good. Isolating the 1st Nexus.

Date: 2015-06-23 12:09:06 UTC
# sh fex
FEX FEX FEX FEX Fex
Number Description State Model Serial
------------------------------------------------------------------------
100 FEX0100 Online N2K-C2248TP-1GE SSI1444081Y
101 FEX0101 Online N2K-C2248TP-1GE SSI1444081S
102 FEX0102 Online N2K-C2248TP-1GE SSI15330JJV
103 FEX0103 Online N2K-C2248TP-1GE SSI153508ET
104 FEX0104 Online N2K-C2248TP-1GE SSI15391ATG
105 FEX0105 Connected N2K-C2232PP-10GE SSI1541037V
106 FEX0106 Connected N2K-C2232PP-10GE SSI14160FXW
107 FEX0107 Online N2K-C2232PP-10GE SSI153409GJ
108 FEX0108 Connected N2K-C2232PP-10GE SSI14160MT9
109 FEX0109 Connected N2K-C2232PP-10GE SSI154103G2
110 FEX0110 Connected N2K-C2232PP-10GE SSI15380LY5
111 FEX0111 Connected N2K-C2248TP-1GE SSI144506KC

Date: 2015-06-23 12:08:53 UTC
Reload okay. I will remount the FEX on this Nexus to reload the 1st one.

Date: 2015-06-23 12:08:27 UTC
# reload power-cycle
WARNING: This command will reboot the system
Do you want to continue? (y/n) [n] y

Date: 2015-06-23 11:49:21 UTC
Performing supervisor state verification.
SUCCESS

Supervisor non-disruptive upgrade successful.

Install has been successful.

Date: 2015-06-23 11:49:13 UTC
Module 1: Refreshing compact flash and upgrading bios/loader/bootrom/power-seq.
Warning: please do not remove or power off the module at this time.
Note: Power-seq upgrade needs a power-cycle to take into effect.
Use command 'reload power-cycle'
Note: Micro-controller upgrade needs a power-cycle to take into effect.
On success of micro-controller upgrade, SWITCH OFF THE POWER to the system and then, power it up.

Need to do a hard reset or power cycle reload to update the power sequencer.

Date: 2015-06-23 11:48:35 UTC
Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive reset
2 yes non-disruptive rolling
3 yes non-disruptive rolling



Images will be upgraded according to following table:
Module Image Running-Version New-Version Upg-Required
------ ---------------- ---------------------- ---------------------- ------------
1 system 6.0(2)N2(2) 7.0(5)N1(1a) yes
1 kickstart 6.0(2)N2(2) 7.0(5)N1(1a) yes
1 bios v3.6.0(05/09/2012) v3.6.0(05/09/2012) no
1 power-seq v1.0 v3.0 yes
1 SFP-uC v1.0.0.0 v1.0.0.0 no
2 power-seq v1.0 v1.0 no
3 power-seq v2.0 v2.0 no
1 microcontroller v1.2.0.1 v1.2.0.1 no


Do you want to continue with the installation (y/n)? [n] y

Install is in progress, please wait.

Performing runtime checks.
[####################] 100% -- SUCCESS

Notifying services about the upgrade.
[####################] 100% -- SUCCESS

Setting boot variables.
[# ] 0%

Date: 2015-06-23 11:48:23 UTC
The install is okay on the 1st n5

Module 117: Non-disruptive upgrading.
SUCCESS

Install has been successful.

Software
BIOS: version 3.6.0
loader: version N/A
kickstart: version 7.0(5)N1(1a)
system: version 7.0(5)N1(1a)




Running the ISSU on the 2nd (the fexs are still not linked up - it shouldn't take long)
# install all kickstart bootflash:n5000-uk9-kickstart.7.0.5.N1.1a.bin system bootflash:n5000-uk9.7.0.5.N1.1a.bin

Verifying image bootflash:/n5000-uk9-kickstart.7.0.5.N1.1a.bin for boot variable \"kickstart\".
[####################] 100% -- SUCCESS

Verifying image bootflash:/n5000-uk9.7.0.5.N1.1a.bin for boot variable \"system\".
[####################] 100% -- SUCCESS

Verifying image type.
[########### ] 50%

Date: 2015-06-23 11:47:19 UTC
the last FEX in progress

Module 115: Non-disruptive upgrading.
SUCCESS

Module 116: Non-disruptive upgrading.
SUCCESS

Module 117: Non-disruptive upgrading.

Date: 2015-06-23 11:47:04 UTC
Module 111: Non-disruptive upgrading.
SUCCESS

Module 112: Non-disruptive upgrading.
SUCCESS

Module 113: Non-disruptive upgrading.


Date: 2015-06-23 11:46:57 UTC
Pre-loading modules.
SUCCESS

Module 100: Non-disruptive upgrading.
SUCCESS

Module 101: Non-disruptive upgrading.
SUCCESS

Module 102: Non-disruptive upgrading.
SUCCESS

Module 103: Non-disruptive upgrading.

Date: 2015-06-23 11:46:43 UTC
finally the 1st FEX is starting to update

Continuing with installation process, please wait.
The login will be disabled until the installation is completed.

Performing supervisor state verification.
SUCCESS

Supervisor non-disruptive upgrade successful.

Pre-loading modules.
SUCCESS

Module 100: Non-disruptive upgrading.

Date: 2015-06-23 11:46:18 UTC
yeah!
let's go
Notifying services about system upgrade.
[####################] 100% -- SUCCESS



Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive reset
2 yes non-disruptive rolling
3 yes non-disruptive rolling
100 yes non-disruptive rolling
101 yes non-disruptive rolling
102 yes non-disruptive rolling
103 yes non-disruptive rolling
104 yes non-disruptive rolling
105 yes non-disruptive rolling
106 yes non-disruptive rolling
107 yes non-disruptive rolling
108 yes non-disruptive rolling
109 yes non-disruptive rolling
110 yes non-disruptive rolling
111 yes non-disruptive rolling
112 yes non-disruptive rolling
113 yes non-disruptive rolling
114 yes non-disruptive rolling
115 yes non-disruptive rolling
116 yes non-disruptive rolling
117 yes non-disruptive rolling



Images will be upgraded according to following table:
Module Image Running-Version New-Version Upg-Required
------ ---------------- ---------------------- ---------------------- ------------
1 system 6.0(2)N2(2) 7.0(5)N1(1a) yes
1 kickstart 6.0(2)N2(2) 7.0(5)N1(1a) yes
1 bios v3.6.0(05/09/2012) v3.6.0(05/09/2012) no
1 power-seq v1.0 v3.0 yes
1 SFP-uC v1.0.0.0 v1.0.0.0 no
2 power-seq v1.0 v1.0 no
3 power-seq v2.0 v2.0 no
100 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
101 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
102 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
103 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
104 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
105 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
106 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
107 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
108 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
109 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
110 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
111 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
112 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
113 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
114 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
115 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
116 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
117 fexth 6.0(2)N2(2) 7.0(5)N1(1a) yes
1 microcontroller v1.2.0.1 v1.2.0.1 no


Do you want to continue with the installation (y/n)? [n] y

Install is in progress, please wait.

Performing runtime checks.
[####################] 100% -- SUCCESS

Notifying services about the upgrade.
[####################] 100% -- SUCCESS

Setting boot variables.
[# ] 0%


Date: 2015-06-23 11:45:39 UTC
still problems...

# install all kickstart bootflash:n5000-uk9-kickstart.7.0.5.N1.1a.bin system bootflash:n5000-uk9.7.0.5.N1.1a.bin
Pre-upgrade check failed. Return code 0x40930062 (free space in the filesystem is below threshold).

# sh system internal flash
Mount-on 1K-blocks Used Available Use% Filesystem
/ 409600 78636 330964 20 /dev/root
/proc 0 0 0 0 proc
/post 2048 4 2044 1 none
/var 409600 78636 330964 20 none
/sys 0 0 0 0 none
/isan 1536000 732476 803524 48 none
/var/tmp 307200 3304 303896 2 none
/var/sysmgr 1024000 1024000 0 100 none <<<<<<<<<<< full 100%
/nxos/tmp 40960 36 40924 1 none
/var/sysmgr/ftp 409600 84 409516 1 none
/var/sysmgr/ftp/cores 102400 0 102400 0 none
/callhome 61440 0 61440 0 none
/dev/shm 524288 288972 235316 56 none
/volatile 153600 4 153596 1 none
/debug 20480 0 20480 0 none
/dev/mqueue 0 0 0 0 none
/debugfs 0 0 0 0 nodev
/mnt/plog 49024 1344 47680 3 /dev/mtdblock2
/mnt/cfg/0 114171 5584 102692 6 /dev/sda5
/mnt/cfg/1 113193 5584 101765 6 /dev/sda6
/var/sysmgr/startup-cfg 409600 16652 392948 5 none
/dev/pts 0 0 0 0 devpts
/mnt/pss 114203 6370 101937 6 /dev/sda4
/bootflash 1612212 620708 909604 41 /dev/sda3
/proc/bus/usb 0 0 0 0 none
/cgroup 0 0 0 0 vdccontrol

after installing a plugin ... we're good

inux(debug)# df -h | grep sysmgr
none 1000M 4.0K 1000M 1% /var/sysmgr
none 400M 84K 400M 1% /var/sysmgr/ftp
none 100M 0 100M 0% /var/sysmgr/ftp/cores
none 400M 17M 384M 5% /var/sysmgr/startup-cfg
Linux(debug)# exit
exit
#

# install all kickstart bootflash:n5000-uk9-kickstart.7.0.5.N1.1a.bin system bootflash:n5000-uk9.7.0.5.N1.1a.bin

Verifying image bootflash:/n5000-uk9-kickstart.7.0.5.N1.1a.bin for boot variable \"kickstart\".
[####################] 100% -- SUCCESS

Verifying image bootflash:/n5000-uk9.7.0.5.N1.1a.bin for boot variable \"system\".
[####################] 100% -- SUCCESS

Verifying image type.
[####################] 100% -- SUCCESS

Extracting \"system\" version from image bootflash:/n5000-uk9.7.0.5.N1.1a.bin.
[####################] 100% -- SUCCESS

Extracting \"kickstart\" version from image bootflash:/n5000-uk9-kickstart.7.0.5.N1.1a.bin.
[####################] 100% -- SUCCESS

Extracting \"bios\" version from image bootflash:/n5000-uk9.7.0.5.N1.1a.bin.
[# ] 0%

Date: 2015-06-23 11:42:28 UTC
On the reload, the n5s reloaded on eth_port_sec ....

Kernel uptime is 0 day(s), 0 hour(s), 4 minute(s), 40 second(s)

Last reset at 256954 usecs after Mon Jun 22 22:47:15 2015

Reason: Reset triggered due to HA policy of Reset
System version: 6.0(2)N2(2)
Service: eth_port_sec hap reset

Leaving the port-channels shut and running ISSU on the one that's still up.

Date: 2015-06-23 11:41:33 UTC
# sh fex
FEX FEX FEX FEX Fex
Number Description State Model Serial
------------------------------------------------------------------------
102 FEX0102 Offline N2K-C2248TP-1GE SSI15330JJV
103 FEX0103 Offline N2K-C2248TP-1GE SSI153508ET
104 FEX0104 Offline N2K-C2248TP-1GE SSI15391ATG
105 FEX0105 Offline N2K-C2232PP-10GE SSI1541037V
106 FEX0106 Offline N2K-C2232PP-10GE SSI14160FXW
107 FEX0107 Offline N2K-C2232PP-10GE SSI153409GJ
108 FEX0108 Offline N2K-C2232PP-10GE SSI14160MT9
109 FEX0109 Offline N2K-C2232PP-10GE SSI154103G2
110 FEX0110 Offline N2K-C2232PP-10GE SSI15380LY5
111 FEX0111 Offline N2K-C2248TP-1GE SSI144506KC
112 FEX0112 Offline N2K-C2232PP-10GE SSI154309WX
113 FEX0113 Offline N2K-C2232TM-E-10GE SSI18420A01
114 FEX0114 Offline N2K-C2232TM-E-10GE SSI1845091Q
115 FEX0115 Offline N2K-C2232TM-E-10GE SSI184906NR
116 FEX0116 Offline N2K-C2232TM-E-10GE SSI185007M9
117 FEX0117 Offline N2K-C2232TM-E-10GE SSI184906NQ

reloading

# wr
[########################################] 100%
Copy complete, now saving to disk (please wait)...

# reload
WARNING: This command will reboot the system
Do you want to continue? (y/n) [n] y

Date: 2015-06-23 11:41:14 UTC
Cutting the FEX 2 port-channel in 2 to reload.

Date: 2015-06-23 11:40:31 UTC
next step ... the microcontroller version is out-of-date
Software
BIOS: version 3.6.0
loader: version N/A
kickstart: version 6.0(2)N2(2)
system: version 6.0(2)N2(2)
Power Sequencer Firmware:
Module 1: version v1.0
Module 2: version v1.0
Module 3: version v2.0
Microcontroller Firmware: version v1.2.0.1
SFP uC: Module 1: v0.0.0.0 <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< ça devrait être en v1.0
QSFP uC: Module not detected
BIOS compile time: 05/09/2012
kickstart image file is: bootflash:///n5000-uk9-kickstart.6.0.2.N2.2.bin
kickstart compile time: 10/4/2013 12:00:00 [10/04/2013 21:10:23]
system image file is: bootflash:///n5000-uk9.6.0.2.N2.2.bin
system compile time: 10/4/2013 12:00:00 [10/04/2013 23:29:49]

I need to reload the chassis ... the traffic will be redirected by the 2nd n5


Date: 2015-06-23 11:37:36 UTC
It worked !


# sh fex
FEX FEX FEX FEX Fex
Number Description State Model Serial
------------------------------------------------------------------------
100 FEX0100 Online N2K-C2248TP-1GE SSI1444081Y
101 FEX0101 Online N2K-C2248TP-1GE SSI1444081S
102 FEX0102 Online N2K-C2248TP-1GE SSI15330JJV
103 FEX0103 Online N2K-C2248TP-1GE SSI153508ET
104 FEX0104 Online N2K-C2248TP-1GE SSI15391ATG
105 FEX0105 Online N2K-C2232PP-10GE SSI1541037V
106 FEX0106 Online N2K-C2232PP-10GE SSI14160FXW
107 FEX0107 Online N2K-C2232PP-10GE SSI153409GJ
108 FEX0108 Online N2K-C2232PP-10GE SSI14160MT9
109 FEX0109 Online N2K-C2232PP-10GE SSI154103G2
110 FEX0110 Online N2K-C2232PP-10GE SSI15380LY5
111 FEX0111 Online N2K-C2248TP-1GE SSI144506KC
112 FEX0112 Online N2K-C2232PP-10GE SSI154309WX
113 FEX0113 Online N2K-C2232TM-E-10GE SSI18420A01
114 FEX0114 Online N2K-C2232TM-E-10GE SSI1845091Q
115 FEX0115 Online N2K-C2232TM-E-10GE SSI184906NR
116 FEX0116 Online N2K-C2232TM-E-10GE SSI185007M9
117 FEX0117 Online N2K-C2232TM-E-10GE SSI184906NQ

Date: 2015-06-23 11:37:26 UTC
I disabled the module 2 ports to force the traffic to flow via the 2nd switch

# sh int status module 2

--------------------------------------------------------------------------------
Port Name Status Vlan Duplex Speed Type
--------------------------------------------------------------------------------
Eth2/1 fex 100|EG disabled 1 full 10G Fabric Exte
Eth2/2 -- sfpAbsent 1 full 10G --
Eth2/3 -- sfpAbsent 1 full 10G --
Eth2/4 -- sfpAbsent 1 full 10G --
Eth2/5 -- sfpAbsent 1 full 10G --
Eth2/6 -- sfpAbsent 1 full 10G --
Eth2/7 fex 104|EG disabled 1 full 10G Fabric Exte
Eth2/8 -- sfpAbsent 1 full 10G --
Eth2/9 -- sfpAbsent 1 full 10G --
Eth2/10 fex117|EG notconnec 1 full 10G Fabric Exte
Eth2/11 -- sfpAbsent 1 full 10G --
Eth2/12 -- sfpAbsent 1 full 10G --
Eth2/13 fex113 notconnec 1 full 10G Fabric Exte
Eth2/14 -- sfpAbsent 1 full 10G --
Eth2/15 fex110|MG notconnec 1 full 10G Fabric Exte
Eth2/16 -- sfpAbsent 1 full 10G --
#

power off module2

# conf te
Enter configuration commands, one per line. End with CNTL/Z.

(config)# poweroff module 2
(config)#
(config)#
(config)#
(config)#
(config)# sh module
Mod Ports Module-Type Model Status
--- ----- ----------------------------------- ---------------------- ------------
1 32 O2 32X10GE/Modular Universal Platfo N5K-C5548UP-SUP active *
2 16 O2 16X10GE Ethernet Module N55-M16P present(powered-off)
3 0 O2 Non L3 Daughter Card N55-DL2 ok

Mod Sw Hw World-Wide-Name(s) (WWN)
--- -------------- ------ ----------------------------------------------------
1 6.0(2)N2(2) 1.0 --
2 6.0(2)N2(2) 1.0 --
3 6.0(2)N2(2) 1.0 --

Mod MAC-Address(es) Serial-Num
--- -------------------------------------- ----------
1 547f.ee1a.8fa8 to 547f.ee1a.8fc7 FOC153255P4
2 002a.6abc.b690 to 002a.6abc.b69f FOC18161R48
3 0000.0000.0000 to 0000.0000.000f FOC15321UJM
(config)#

module up

(config)# no poweroff module 2
(config)#


Date: 2015-06-23 11:35:50 UTC
Some ports are in compatibility check failed for speed.
The n5 A is not seeing the same speed as B in certain instances. The traffic is blackholed (another bug fixed in 7.0.5.n1a)

# sh vpc | i fail
101378 Eth100/1/3 up failed Compatibility check failed -
101379 Eth100/1/4 up failed Compatibility check failed -
101380 Eth100/1/5 up failed Compatibility check failed -
101381 Eth100/1/6 up failed Compatibility check failed -
101386 Eth100/1/11 up failed Compatibility check failed -
101396 Eth100/1/21 up failed Compatibility check failed -
101399 Eth100/1/24 up failed Compatibility check failed -
101410 Eth100/1/35 up failed Compatibility check failed -
101411 Eth100/1/36 up failed Compatibility check failed -
101417 Eth100/1/42 up failed Compatibility check failed -
101420 Eth100/1/45 up failed Compatibility check failed -
102405 Eth101/1/6 up failed Compatibility check failed -
102419 Eth101/1/20 up failed Compatibility check failed -
102432 Eth101/1/33 up failed Compatibility check failed -
102436 Eth101/1/37 up failed Compatibility check failed -
102440 Eth101/1/41 up failed Compatibility check failed -
102445 Eth101/1/46 up failed Compatibility check failed -
102447 Eth101/1/48 up failed Compatibility check failed -
103430 Eth102/1/7 up failed Compatibility check failed -
103433 Eth102/1/10 up failed Compatibility check failed -
103442 Eth102/1/19 up failed Compatibility check failed -
103449 Eth102/1/26 up failed Compatibility check failed -
103451 Eth102/1/28 up failed Compatibility check failed -
103455 Eth102/1/32 up failed Compatibility check failed -
103462 Eth102/1/39 up failed Compatibility check failed -
104450 Eth103/1/3 up failed Compatibility check failed -
104455 Eth103/1/8 up failed Compatibility check failed -
104456 Eth103/1/9 up failed Compatibility check failed -
104460 Eth103/1/13 up failed Compatibility check failed -
104478 Eth103/1/31 up failed Compatibility check failed -
104481 Eth103/1/34 up failed Compatibility check failed -
1044 Eth103/1/35 up failed Compatibility check failed -
104484 Eth103/1/37 up failed Compatibility check failed -
104488 Eth103/1/41 up failed Compatibility check failed -
105473 Eth104/1/2 up failed Compatibility check failed -
105479 Eth104/1/8 up failed Compatibility check failed -
105486 Eth104/1/15 up failed Compatibility check failed -
105499 Eth104/1/28 up failed Compatibility check failed -
105501 Eth104/1/30 up failed Compatibility check failed -
105507 Eth104/1/36 up failed Compatibility check failed -

we performed a shut/no shut on the impacted ports to fix them

# sh vpc | i fail
#
Posted Jun 23, 2015 - 11:34 UTC