OVHcloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance

rbx-g1-a9

Scheduled Maintenance Report for Network & Infrastructure

Completed

Nous allons mettre à jour le routeur rbx-g1-a9. On va lui changer
les costs OSPF durant l'upgrade à cause de l'ISSU qui ne fonctionne
pas sur les ASR.

Update(s):

Date: 2011-01-27 07:48:02 UTC
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#upgrade hw-module fpd all location all
Thu Jan 27 07:47:24.261 UTC

Starting the upgrade/download of following FPD:
=========== ==== ======= ======= =========== =========
Current Upg/Dng
Location Type Subtype Upg/Dng Version Version
=========== ==== ======= ======= =========== =========
0/RSP0/CPU0 lc rommon upg 1.04 1.05
------------------------------------------------------
Starting the upgrade/download of following FPD:
=========== ==== ======= ======= =========== =========
Current Upg/Dng
Location Type Subtype Upg/Dng Version Version
=========== ==== ======= ======= =========== =========
0/RSP1/CPU0 lc rommon upg 1.04 1.05
------------------------------------------------------

FPD upgrade has ended.

c'est fini :)

Date: 2011-01-27 07:47:16 UTC
RP/0/RSP0/CPU0:rbx-g1-a9(admin)# sh install committed summary
Thu Jan 27 07:47:00.310 UTC
Default Profile:
SDRs:
Owner
Committed Packages:
disk0:asr9k-mini-p-4.0.1
disk0:asr9k-doc-p-4.0.1
disk0:asr9k-k9sec-p-4.0.1
disk0:asr9k-mpls-p-4.0.1
disk0:asr9k-mgbl-p-4.0.1
disk0:asr9k-mcast-p-4.0.1

RP/0/RSP0/CPU0:rbx-g1-a9(admin)# sh install active summary
Thu Jan 27 07:47:04.734 UTC
Default Profile:
SDRs:
Owner
Active Packages:
disk0:asr9k-mini-p-4.0.1
disk0:asr9k-doc-p-4.0.1
disk0:asr9k-k9sec-p-4.0.1
disk0:asr9k-mpls-p-4.0.1
disk0:asr9k-mgbl-p-4.0.1
disk0:asr9k-mcast-p-4.0.1

RP/0/RSP0/CPU0:rbx-g1-a9(admin)# sh install inactive summary
Thu Jan 27 07:47:10.346 UTC
There are no inactive packages on the router.

RP/0/RSP0/CPU0:rbx-g1-a9(admin)#

Date: 2011-01-27 07:46:38 UTC
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install commit
Thu Jan 27 07:40:49.157 UTC
Install operation 115 '(admin) install commit' started by user 'octave' via CLI at 07:40:49 UTC Thu Jan 27 2011.
Error: Cannot proceed with the operation because the upgrade package disk0:asr9k-upgrade-p-4.0.1 is active.
Error:
Error: The disk0:asr9k-upgrade-p-4.0.1 package should only be used when upgrading from software versions prior to 4.0.0. Once the upgrade is complete, it should be immediately deactivated and removed. No
Error: further install operations will be allowed until this is completed.
Error:
Error: Deactivate the package disk0:asr9k-upgrade-p-4.0.1 from the entire router by executing the 'install deactivate disk0:asr9k-upgrade-p-4.0.1' command in admin mode.
Error: Remove the package disk0:asr9k-upgrade-p-4.0.1 from the entire router by executing the 'install remove disk0:asr9k-upgrade-p-4.0.1' command in admin mode.
Error: No further install operations will be allowed until this is completed.
Install operation 115 failed at 07:40:49 UTC Thu Jan 27 2011.
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install deactivate disk0:asr9k-upgrade-p-4.0.1 sync
Thu Jan 27 07:41:02.963 UTC
Install operation 116 '(admin) install deactivate disk0:asr9k-upgrade-p-4.0.1 synchronous' started by user 'octave' via CLI at 07:41:03 UTC Thu Jan 27 2011.
Info: Install Method: Parallel Process Restart
Info: The changes made to software configurations will not be persistent across system reloads. Use the command '(admin) install commit' to make changes persistent.
Info: Please verify that the system is consistent following the software change using the following commands:
Info: show system verify
Info: install verify packages
Install operation 116 completed successfully at 07:42:16 UTC Thu Jan 27 2011.
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install remove disk0:asr9k-upgrade-p-4.0.1 sync
Thu Jan 27 07:42:23.192 UTC
Install operation 117 '(admin) install remove disk0:asr9k-upgrade-p-4.0.1 synchronous' started by user 'octave' via CLI at 07:42:23 UTC Thu Jan 27 2011.
Info: This operation will remove the following packages:
Info: disk0:asr9k-doc-4.0.1
Info: disk0:asr9k-adv-video-4.0.1
Info: disk0:asr9k-sbc-4.0.1
Info: disk0:asr9k-k9sec-4.0.1
Info: disk0:asr9k-diags-4.0.1
Info: disk0:asr9k-mgbl-4.0.1
Info: disk0:asr9k-mcast-4.0.1
Info: disk0:asr9k-mpls-4.0.1
Info: disk0:asr9k-rout-4.0.1
Info: disk0:asr9k-fwdg-4.0.1
Info: disk0:asr9k-lc-4.0.1
Info: disk0:asr9k-admin-4.0.1
Info: disk0:asr9k-upgrade-p-4.0.1
Info: After this install remove the following install rollback point will no longer be reachable, as the required packages will not be present:
Info: 114
Proceed with removing these packages? [confirm]

ce message n'est pas vrai. il ne remove pas tous les autres fichiers.

Install operation 117 completed successfully at 07:42:42 UTC Thu Jan 27 2011.
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#sh install active sum
Thu Jan 27 07:42:53.757 UTC
Default Profile:
SDRs:
Owner
Active Packages:
disk0:asr9k-mini-p-4.0.1
disk0:asr9k-doc-p-4.0.1
disk0:asr9k-k9sec-p-4.0.1
disk0:asr9k-mpls-p-4.0.1
disk0:asr9k-mgbl-p-4.0.1
disk0:asr9k-mcast-p-4.0.1

RP/0/RSP0/CPU0:rbx-g1-a9(admin)#sh install comm sum
Thu Jan 27 07:43:00.159 UTC
Default Profile:
SDRs:
Owner
Committed Packages:
disk0:asr9k-mini-p-4.0.0
disk0:asr9k-doc-p-4.0.0
disk0:asr9k-k9sec-p-4.0.0
disk0:asr9k-mpls-p-4.0.0
disk0:asr9k-mgbl-p-4.0.0
disk0:asr9k-mcast-p-4.0.0

RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install commit
Thu Jan 27 07:43:08.837 UTC
Install operation 118 '(admin) install commit' started by user 'octave' via CLI at 07:43:09 UTC Thu Jan 27 2011.
Install operation 118 completed successfully at 07:43:12 UTC Thu Jan 27 2011.
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#sh install comm sum
Thu Jan 27 07:43:15.132 UTC
Default Profile:
SDRs:
Owner
Committed Packages:
disk0:asr9k-mini-p-4.0.1
disk0:asr9k-doc-p-4.0.1
disk0:asr9k-k9sec-p-4.0.1
disk0:asr9k-mpls-p-4.0.1
disk0:asr9k-mgbl-p-4.0.1
disk0:asr9k-mcast-p-4.0.1

RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install remove inactive synchronous
Thu Jan 27 07:43:30.072 UTC
Install operation 119 '(admin) install remove inactive synchronous' started by user 'octave' via CLI at 07:43:30 UTC Thu Jan 27 2011.
Info: This operation will remove the following packages:
Info: disk0:asr9k-mpls-p-4.0.0
Info: disk0:iosxr-mpls-4.0.0
Info: disk0:asr9k-mini-p-4.0.0
Info: disk0:asr9k-fpd-4.0.0
Info: disk0:asr9k-cpp-4.0.0
Info: disk0:asr9k-scfclient-4.0.0
Info: disk0:asr9k-diags-supp-4.0.0
Info: disk0:asr9k-fwding-4.0.0
Info: disk0:asr9k-base-4.0.0
Info: disk0:asr9k-os-mbi-4.0.0
Info: disk0:iosxr-diags-4.0.0
Info: disk0:iosxr-routing-4.0.0
Info: disk0:iosxr-fwding-4.0.0
Info: disk0:iosxr-infra-4.0.0
Info: disk0:asr9k-mgbl-p-4.0.0
Info: disk0:asr9k-mgbl-supp-4.0.0
Info: disk0:iosxr-mgbl-4.0.0
Info: disk0:asr9k-mcast-p-4.0.0
Info: disk0:asr9k-mcast-supp-4.0.0
Info: disk0:iosxr-mcast-4.0.0
Info: disk0:asr9k-k9sec-p-4.0.0
Info: disk0:asr9k-k9sec-supp-4.0.0
Info: disk0:iosxr-security-4.0.0
Info: disk0:asr9k-doc-p-4.0.0
Info: disk0:asr9K-doc-supp-4.0.0
Info: After this install remove the following install rollback points will no longer be reachable, as the required packages will not be present:
Info: 30, 39, 55, 75, 79, 90, 99
Proceed with removing these packages? [confirm]
Install operation 119 completed successfully at 07:45:48 UTC Thu Jan 27 2011.
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#



Date: 2011-01-27 07:40:21 UTC
64 bytes from rbx-g1-a9.routers.ovh.net (94.23.122.19): icmp_seq=98 ttl=252 time=4.37 ms
64 bytes from rbx-g1-a9.routers.ovh.net (94.23.122.19): icmp_seq=99 ttl=252 time=4.53 ms

64 bytes from rbx-g1-a9.routers.ovh.net (94.23.122.19): icmp_seq=545 ttl=250 time=4.55 ms
64 bytes from rbx-g1-a9.routers.ovh.net (94.23.122.19): icmp_seq=546 ttl=250 time=4.49 ms


Date: 2011-01-27 07:33:47 UTC
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install activate id 113 synchronous
Proceed with this install operation (y/n)? [y]
Info: Install Method: Parallel Reload
Info: The changes made to software configurations will not be persistent across system reloads. Use the command '(admin) install commit' to make changes persistent.
Info: Please verify that the system is consistent following the software change using the following commands:
Info: show system verify
Info: install verify packages
Install operation 114 completed successfully at 07:32:14 UTC Thu Jan 27 2011.
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#

RP/0/RSP0/CPU0:rbx-g1-a9#RP/0/RSP0/CPU0:Jan 27 07:32:23 UTC: redcon[297]: %HA-REDCON-1-STANDBY_NOT_READY : standby card is NOT
ready
RP/0/RSP0/CPU0:11w18h:1:39: instdir[208]: %INSTALL-INSTMGR-7-RELOAD_NODE_INFO : The primary install director will now restart
this node using 'disk0:asr9k-os-mbi-4.0.1/mbiasr9k-rp.vm'
[0x32ea1436d4fc8] Record Reboot History, reboot cause = 0x4000047, descr = Cause: pID node reload is required by install opera
tion Process: instdir Traceback: 4c21fb00
4rebooting

Date: 2011-01-27 06:50:30 UTC
la conf est propre on peut y aller

install add source asr9k-doc-p.pie-4.0.1 asr9k-k9sec-p.pie-4.0.1 asr9k-mcast-p.pie-4.0.1 asr9k-mgbl-p.pie-4.0.1 asr9k-mini-p.pie-4.0.1 asr9k-mpls-p.pie-4.0.1 asr9k-upgrade-p.pie-4.0.1 sync

Date: 2011-01-27 06:49:07 UTC
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install remove inactive synchronous
Install operation 112 completed successfully at 06:48:50 UTC Thu Jan 27 2011.


Date: 2011-01-27 06:46:34 UTC
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install commit
Thu Jan 27 06:45:37.600 UTC
Install operation 109 '(admin) install commit' started by user 'octave' via CLI at 06:45:37 UTC Thu Jan 27 2011.
Error: Cannot proceed with the operation because the upgrade package disk0:asr9k-upgrade-p-4.0.0 is present on boot disk.
Error:
Error: The disk0:asr9k-upgrade-p-4.0.0 package should only be used when upgrading from software versions prior to 4.0.0. Once the upgrade is complete, it should be immediately deactivated and removed. No
Error: further install operations will be allowed until this is completed.
Error:
Error: Remove the package disk0:asr9k-upgrade-p-4.0.0 from the entire router by executing the 'install remove disk0:asr9k-upgrade-p-4.0.0' command in admin mode.
Error: No further install operations will be allowed until this is completed.
Install operation 109 failed at 06:45:38 UTC Thu Jan 27 2011.
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install remove disk0:asr9k-upgrade-p-4.0.0 synchronous
Thu Jan 27 06:45:48.094 UTC
Install operation 110 '(admin) install remove disk0:asr9k-upgrade-p-4.0.0 synchronous' started by user 'octave' via CLI at 06:45:48 UTC Thu Jan 27 2011.
Info: This operation will remove the following packages:
Info: disk0:asr9k-doc-4.0.0
Info: disk0:asr9k-adv-video-4.0.0
Info: disk0:asr9k-sbc-4.0.0
Info: disk0:asr9k-k9sec-4.0.0
Info: disk0:asr9k-diags-4.0.0
Info: disk0:asr9k-mgbl-4.0.0
Info: disk0:asr9k-mcast-4.0.0
Info: disk0:asr9k-mpls-4.0.0
Info: disk0:asr9k-rout-4.0.0
Info: disk0:asr9k-fwdg-4.0.0
Info: disk0:asr9k-lc-4.0.0
Info: disk0:asr9k-admin-4.0.0
Info: disk0:asr9k-upgrade-p-4.0.0
Info: After this install remove the following install rollback points will no longer be reachable, as the required packages will not be present:
Info: 30, 75, 90
Proceed with removing these packages? [confirm]
Install operation 110 completed successfully at 06:46:06 UTC Thu Jan 27 2011.
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install commit
Thu Jan 27 06:46:12.073 UTC
Install operation 111 '(admin) install commit' started by user 'octave' via CLI at 06:46:12 UTC Thu Jan 27 2011.
Install operation 111 completed successfully at 06:46:15 UTC Thu Jan 27 2011.
Posted Jan 27, 2011 - 06:41 UTC