Nous allons mettre à jour tous les N5548
afin de mieux gerer les limitations
de serveurs à 200Mbps, 300Mbps et plus
si le client a acheté de la bp en plus.
Update(s):
Date: 2013-03-13 17:19:23 UTC 178.33.241.0/24: done
Date: 2013-03-13 15:31:28 UTC 178.33.241.0/24: doing
Date: 2013-03-13 15:13:33 UTC Le QoS limite le trafic interne alors qu'il
ne devrait pas. On fait le rollback de la
configuration pour le debuggage avec le TAC
de Cisco.
Date: 2013-03-12 16:11:06 UTC 176.31.224.0/24: le A est revenu, mais l'upgrade
de FEX se passe mal.
Continuing with installation process, please wait.
The login will be disabled until the installation is completed.
Performing supervisor state verification.
SUCCESS
Supervisor non-disruptive upgrade successful.
Pre-loading modules.
FAIL. Return code 0x4200000E (Image download failed on the FEX).
Remaining action::
\"Module(s) 100, 101, 102, 103, 104, 105, 106, 107, 108, 109, 111 still need to be upgraded\".
Install has failed. Return code 0x40930069 (Preload of module image failed).
Please identify the cause of the failure, and try 'install all' again.
Date: 2013-03-12 16:05:07 UTC 176.31.236.0/24: le A a planté
Reason: Reset triggered due to HA policy of Reset
System version: 6.0(2)N1(1)
Service: fwm hap reset
Date: 2013-03-11 08:49:03 UTC 46.105.114.0/24: plantage du A
Reason: Reset triggered due to HA policy of Reset
System version: 6.0(2)N1(1)
Service: fwm hap reset
178.33.230.0/24: plantage du A
Reason: Reset triggered due to HA policy of Reset
System version: 6.0(2)N1(1)
Service: fwm hap reset
Date: 2013-03-10 23:54:32 UTC 178.33.63.0/24: done
Date: 2013-03-10 20:37:31 UTC 178.33.63.0/24 ne se passe pas bien:
http://travaux.ovh.net/?do=details&id=8212 Reason: Reset triggered due to HA policy of Reset
System version: 6.0(2)N1(1)
Service: fwm hap reset
Date: 2013-03-10 19:50:39 UTC 178.33.238.0/24: done
178.33.236.0/24: done
178.33.63.0/24: doing
Date: 2013-03-10 19:50:15 UTC 5.135.134.0/24: done